Assigned by the company Van der Leun located in Sliedrecht I prepared a welding procedure for the welding of Inconel 625 on S355J2+N base material. The welding of these components had to be according to ISO 15614-7 with the additional requirement that there would be a maximum of 5% FE at 5mm above the fusion line. All the testing have been conducted by MME Ridderkerk and
took place after Post Weld Heat Treatment by Akkermans Gloeitechniek.
Weld cut trough (macro view) of the overlay: Start of the first weld layer.